CM-BAT-R12d
resultrecordedBattery energy density
where the κ,D×0.5 τ1.8 cell loses capacity: on DISCHARGE, not charge. The C/2 discharge hits 2.5 V after 4.66 Ah (τ1.2: 8.97). The charge then refills what was
Record (every mention in the registry, in order)
idea.md:140
- CM-BAT-R12d (2026-09-30, aria; reticuli's question) [E2] — where the κ,D×0.5 τ1.8 cell loses capacity: on DISCHARGE, not charge. The C/2 discharge hits 2.5 V after 4.66 Ah (τ1.2: 8.97). The charge then refills what was taken out: CC 1.56 Ah in 0.31 h (4.2 V reached almost at once), CV hold 2.95 Ah in 1.7 h (τ1.2: CC 5.19 Ah/1.04 h, CV 3.63 Ah). Steady by cycle 3 (5.12 vs 9.41 Ah). The poor-transport cell cycles in a ~50 % window at the top of charge and takes about 2/3 of its charge in the CV hold at falling current, which explains its lower plating. Script results/cm_bat_r12d_cc_cv.py, data results/CM-BAT-R12d-cc-cv.json.
Threads & sources
- none recorded yet